The authors introduced a new method of measuring the range of wrist motion using the iPhone 4 Gyroscope application that is simpler to use and can be performed by the patient outside a clinical setting. Range of active motion (degreesstandard deviation) Rexion 73.9 6.386. It is normal to feel some discomfort at first, but you should not feel pain. The aim of this study is to compare normal wrist ROM and grip strength in a Caucasian, Southern Chinese and Japanese population.
#WRIST NORMAL RANGE OF MOTION FULL#
The differences in average value were not statistically significant. These exercises help you move each joint through its full range of motion. The differences between the measurement values by the Gyroscope application and average value were 0.7 degrees for flexion, -0.2 degrees for extension, 0.5 degrees for radial deviation, 0.7 degrees for ulnar deviation, 0.4 degrees for supination, and 0.8 degrees for pronation. The average measurement values obtained using the iPhone 4 Gyroscope application were 73.7 (5.5) degrees for flexion, 70.8 (5.1) degrees for extension, 19.5 (3.0) degrees for radial deviation, 33.7 (3.9) degrees for ulnar deviation, 140.4 (5.7) degrees for supination, and 60.8 (4.9) degrees for pronation. Wrist Radioulnar Deviation: Dorsal view of hand and wrist exhibiting normal deviation in the range of movement possible laterally versus medially when bent at. Normal values for wrist ROM are 73 degrees of flexion, 71 degrees of extension, 19 degrees of radial deviation, 33 degrees of ulnar deviation, 140 degrees of supination, and 60 degrees of pronation.The average measurement values obtained using the goniometer were 74.2 (5.1) degrees for flexion, 71.1 (4.9) degrees for extension, 19.7 (3.0) degrees for radial deviation, 34.0 (3.7) degrees for ulnar deviation, 140.8 (5.6) degrees for supination, and 61.1 (4.7) degrees for pronation. Range of Motion Wrist Extension: 60-75 Wrist Radial Deviation: 20- Wrist Ulnar Deviation: 30-40 MCP Flexion: active (90-100) passive (slightly more) MCP. Participants did not have previous wrist illnesses and their measured values for wrist motion were compared in each direction. This study was performed using 52 healthy participants to compare wrist ROM measurement using a universal goniometer and the iPhone 4 Gyroscope application. Twelve healthy young men (age 19-3 1 years) and. The most common method for performing this task is by using a universal goniometer. signals of the electrogoniometer, and the ROM (range of motion) Index for wrist circumduction was defined. Measuring the range of motion (ROM) of the wrist is an important physical examination conducted in the Department of Hand Surgery for the purpose of evaluation, diagnosis, prognosis, and treatment of patients.